← CASSACA

DECam Exposure Time Calculator

The SCIDOC 0494 (ETC Ver.7) formulas for DECam. Broadband bands use the spreadsheet's band averages; narrowbands integrate the measured filter curve. Reports S/N, 5σ depth, and wall-clock time including readout.

ETC Ver.7 · broadband + narrowband

Inputs

—

Total exposure = single × count, and each exposure is read out separately. The xls "exposure time" is the total.

Sky

—

—

Timing overhead

17 s is the full-frame DECam readout (250 kpix/s, DECam Imager manual); the telescope can slew during readout.

Throughput and detector

Result

S/N · total exposure — —
5σ point-source depth
—AB
Exposure for target S/N
—s
S/N per exposure
—
Wall-clock total
—h

Time breakdown

Wall-clock = on-sky exposure + readout + per-frame overhead, counted for every exposure, plus the fixed overhead.

Exposure (on-sky)— s
Readout —— s
Other per-frame overhead— s
Fixed overhead— s
Wall-clock total— s · — h

Noise budget (total exposure, all readouts)

Source — e⁻ Sky — e⁻ Readout — e⁻²

—

S/N vs magnitude (total exposure)

Magnitude20222426
S/N————

Verification against scidoc0494.xls

— · click to expand

Uses the spreadsheet's own inputs for each band (R22, R23, R39–R44, R50; magnitude 20; one read) and recomputes S/N with the same formulas.

BandCWLBandpassT_totSky xls S/NPage S/NΔ

What each row computes

The original sheet has one column per broadband and one row per quantity. The formulas were decompiled from the file itself.

Reading the result

The headline S/N is for the total exposure; the per-exposure S/N is shown separately. Read noise grows as √N because every exposure is read out.

For narrowbands the 5σ depth uses the integrated filter curve; for broadbands it uses the spreadsheet's band average, so the two modes are not directly comparable at the 0.1 mag level.

Every value recomputes on each keystroke. If an input is empty or out of range the result is blanked and the field is outlined, so no stale number is left on screen.

This parameter set

—

Filter quantities: —